Section VIII: Service and Cleaning

NOTICE

BURNER SHUTDOWN: Open Service Switch

to turn off burner.
Manual Oil Supply Valve should be closed

and Electric Service to boiler turned off if

boiler will not be operated for an extended

period of time.

A

. General. Inspection, service and cleaning should

be conducted annually. Turn off electric power and

close oil supply valve while conducting service or

maintenance.

B

. Firetubes and Combustion Chamber.

1. CLEAN THE FIRETUBES

a. For access to fireside of boiler, pull two halves

of Burner Swing Door Interlock wiring harness

apart, remove fasteners holding door closed and

open swing door.

b. Prior to cleaning boiler, lay a protective cloth or

plastic over combustion chamber liner.

c. Using a 1 1/2" diameter wire brush (30" handle),

clean firetubes. Measure 15" from end of brush

opposite handle, and mark handle. DO NOT

allow this mark to go past front end of firetube

during cleaning, or brush will hit rear door

insulation piece.

2. CLEAN THE COMBUSTION CHAMBER
Using wire or fiber bristle brush, clean inside of

combustion chamber. DO NOT let brush hit rear

door insulation piece or combustion chamber liner.

3. AFTER CLEANING

a. Vacuum debris inside bottom of rear door,

remove protective cloth, and vacuum remaining

fireside of boiler as necessary. BE CAREFUL

not to damage liner or rear door insulation piece.

Inspect front and rear door insulation pieces,

front door gaskets and combustion chamber liner

for damage. Replace any damaged pieces.

4. CLOSE BOILER
CAUTION: Do not start burner unless burner swing

door is securely closed. Close door, install fasteners,

and tighten securely. Door should be parallel

to tubesheet when viewed from top and sides.

Reconnect two halves of Swing Door Interlock.

C.

Vent/Air Intake System. Inspect for obstructions, soot

accumulation, proper support, and deterioration of pipe,

fittings, and joints.
1. Inspect inside of vent pipe.

a. Disconnect appliance adapter from boiler flue

collar.

b. Remove any obstructions and clean with a wire

brush as required.

c. Reconnect appliance adapter to boiler flue collar

as detailed in Section IV: Venting/Air Intake

Piping.

2. Clean terminal screens. Terminals must be free of

obstruction, undamaged, with screens securely in

place.

3. Terminal and wall thimbles (if used) must be

weather-tight.

4. Pipe must be full round shape, and show no damage

from impact or excessive temperature.

5. Pipe must be supported at minimum 5 foot intervals

and must not sag.

6. All vent joints must be secure and watertight.
7. All air intake joints must be secure and airtight.

D.

Burner.

1. Replace the oil supply line filter.
2. Remove and clean the pump strainer (if applicable).
3. Replace the nozzle with an equivalent nozzle. Refer

to Table 6 for Beckett Burner Settings. Refer to

Table 6a for Riello BF Burner Settings.

4. Clean and inspect the electrodes for damage,

replacing any that are cracked or chipped.

5. Clean the combustion head of all lint and soot.

WARNING

All boiler cleaning must be completed with burner service switch turned off. Boilers equipped with burner

swing door have a potential hazard which can cause severe property damage, personal injury or loss of

life if ignored. Before opening swing door, turn off service switch to boiler to prevent accidental firing of

burner outside the combustion chamber. Be sure to tighten swing door fasteners completely when service

is completed.