background image

1

D.

Air Intake Installation (Indoor Air for Combustion)

1. Remove the black plastic inlet cover from the right

side of the Beckett AFII burner.

6. Install air intake terminal. See Figure 13.
7. Seal all external joints with weatherproof caulk.

WARNING

Do not locate air intake where petroleum distillates,

CFC's, detergents, volatile vapors or any other

chemicals are present. Severe boiler corrosion

and failure will result.

2. Attach the Air Intake Terminal directly to the burner

intake collar.

3. Discard the Vacuum Relief Valve.
Alternate to 1., 2. and 3.:

Keep the black plastic inlet cover in place and

discard the Air Intake Terminal and the Vacuum

Relief Valve.

WARNING

Do not locate air intake termination into a crawl

space or under a deck that also includes the

vent termination, regardless of distance between

terminations.