Lukas Compact Units User Manual
Page 37

37
13.1.2 Noise emissions (in accordance with EN ISO 3744):
type
PC-6
GC-6
DC-6
ref.no.
840729316
840729317
840729319
idle running
(measuring distance: 1m)
[dB(A)]
73
85
93
full load
(measuring distance: 1m)
[dB(A)]
78
89
93,7
idle running
(measuring distance: 5m)
[dB(A)]
65
82
82
full load
(measuring distance: 5m)
[dB(A)]
67
85
83,5
13.2 Recommended hydraulic fluid
13.3 Hoses
13.4 Operating temperature and storage temperature ranges
See separate operating instructions for the hydraulic hoses.
Mineral oil DIN ISO 6743-4 for LUKAS hydraulic equipment and others
Oil temperature range
Oil code
Viscosity rating
Remarks
A
-24 .... +30°C
HL 5
VG 5
B
-18 .... +50°C
HM 10
VG 10
C
-8 .... +75°C
HM 22
VG 22
D
+5 .... +80°C
HM 32
VG 32
E
-8 .... +70°C
HF-E15
VG 15
Bio-oil
Oil temperature range
Oil code
Viscosity rating
Remarks
A
-11.2 .... +86°F
HL 5
VG 5
B
-0.4 .... +122°F
HM 10
VG 10
C
+17.6 .... +167°F
HM 22
VG 22
D
+41.0 .... +176°F
HM 32
VG 32
E
+17.6 .... +158°F
HF-E15
VG 15
Bio-oil
recommended viscosity range: 10...200 mm²/s
(10…200 cSt.)
Supplied with HM 22 DIN ISO 6743-4.
Ambient temperature
(device in operation)
[°C]
-20 …
+55
Storage temperature
(device not in operation)
[°C]
-30 …
+60