13.1.2 Noise emissions (in accordance with EN ISO 3744):

type

PC-6

GC-6

DC-6

ref.no.

840729316

840729317

840729319

idle running

(measuring distance: 1m)

[dB(A)]

73

85

93

full load

(measuring distance: 1m)

[dB(A)]

78

89

93,7

idle running

(measuring distance: 5m)

[dB(A)]

65

82

82

full load

(measuring distance: 5m)

[dB(A)]

67

85

83,5

13.2 Recommended hydraulic fluid

13.3 Hoses

13.4 Operating temperature and storage temperature ranges

See separate operating instructions for the hydraulic hoses.

Mineral oil DIN ISO 6743-4 for LUKAS hydraulic equipment and others

Oil temperature range

Oil code

Viscosity rating

Remarks

A

-24 .... +30°C

HL 5

VG 5

B

-18 .... +50°C

HM 10

VG 10

C

-8 .... +75°C

HM 22

VG 22

D

+5 .... +80°C

HM 32

VG 32

E

-8 .... +70°C

HF-E15

VG 15

Bio-oil

Oil temperature range

Oil code

Viscosity rating

Remarks

A

-11.2 .... +86°F

HL 5

VG 5

B

-0.4 .... +122°F

HM 10

VG 10

C

+17.6 .... +167°F

HM 22

VG 22

D

+41.0 .... +176°F

HM 32

VG 32

E

+17.6 .... +158°F

HF-E15

VG 15

Bio-oil

recommended viscosity range: 10...200 mm²/s

(10…200 cSt.)

Supplied with HM 22 DIN ISO 6743-4.

Ambient temperature

(device in operation)

[°C]

-20 …

+55

Storage temperature

(device not in operation)

[°C]

-30 …

+60