Operation
8.
CAUTION!
Before the motor is started, the hydraulic unit and the control unit must be
switched to
depressurised circulation (for the hydraulic unit, this means
connecting the supply and return lines together, for example). Only in this way is
it possible to start the unit without a hydraulic load.
8.1.1 Gasoline / petrol and diesel engines
Before starting the combustion engines, check that the fuel tank is full and that the engine oil
level is within the permitted tolerances. If necessary, top up the relevant fluid.
Procedure for starting Briggs & Stratton engines:
1. Open gasoline / petrol tap
2. Move the lever from switch position A to switch
position C
3. Pull the starter rope or activate the E starter
Procedure for starting Intek engines:
1. Open gasoline / petrol tap
2. Move top lever from switching position E to switching
position F
3. Move bottom lever (choke) from switching position G
to switching position H
4. Pull the starter rope or activate the E starter
5. When the motor is running, switch bottom lever back
to switching position G.
Procedure for starting Honda engines:
1. Open gasoline / petrol tap
2. Switch the ON/OFF switch to ON.
3. Move lever from switching position J to switching
position K (choke)
4. Pull starter rope
5. When the motor is running, switch lever back to
switching position J
Lever at top
Lever at bottom
A
B
C
E
F
G
H
K
J
8.1 Starting the motors
Please consult the separate operating instructions of the motor manufacturer for the precise
procedure for starting the combustion engine.