beautypg.com

Lukas Compact Units User Manual

Page 32

background image

32

Motor runs but connected

implement does not move

in response to control

command.

Hose assembly not

connected properly or is

damaged

Inspect the connection of

the hose assembly and, if

necessary, reconnect

Defective pump unit

Have repaired by

authorised dealer or

directly by LUKAS

Defective hydraulic

coupling (if fitted)

Replace hydraulic coupling

Problem with the control

unit

Consult the separate

operating instructions for

the control unit.

Problem with the

implement

Consult the separate

operating instructions for

the implement.

Connected implement

moves in response to

control command but only

very slowly or unevenly.

Air in the hydraulic supply Vent the hydraulic system
Defective pump unit

Have repaired by

authorised dealer or

directly by LUKAS

Defective hydraulic

coupling (if fitted)

Replace hydraulic coupling

Pressure relief at

control unit still active

(depressurised circulation)

Consult the separate

operating instructions for

the control unit.

Trouble

Cause

Solution

Connected implement

does not reach its end

position

Insufficient fluid in the

hydraulic reservoir

Top up hydraulic fluid to

the maximum filling level

Attention: return the

implement to the home

position before you top

up the hydraulic fluid.

Usable hydraulic fluid

volume of the unit is

insufficient

Use a different implement

with a usable volume

below the maximum

usable volume of the

hydraulic unit

Connected implement

does not produce its rated

force

Maximum permitted

operating pressure of the

pump is not reached

Have the pressure limiting

valve reset or repaired

by authorised dealer or

directly by LUKAS

Defective hydraulic unit

Have repaired by

authorised dealer or

directly by LUKAS