4 installation and repair of optional accessories – Lukas Compact Units User Manual
Page 28

28
11.4 Installation and repair of optional accessories
11.4.1 Fitting attachment hose reels to the frame
Attachment hose reels usually come prefitted and do not need to be removed unless the
complete hose reel is to be exchanged.
A retrofit kit is available and it contains all the necessary fasteners.
The hose reels differ depending on which side they are to be fitted (left or right). Be sure to
fit the hose reels to the correct side. The hoses should be pulled out in the working direction
from the bottom of the reel.
11.4.2 Hydraulic connection of attachment hose reels with hoses
The hydraulic connection of the attachment hose reels is established in the same way as for
hoses connected directly to the connecting block or valve block of the hydraulic unit.
For instructions on how to connect the hose lines, refer to the procedure described under
“Direct connection” in the “Repairs” chapter
Procedure for fitting an attachment hose reel:
1. Place the carrier plate on the unit frame in such a way that the holes in the carrier plate
are aligned with the holes in the frame.
2. Fit the supplied bolts “A” through the frame and the plate. The bolt head must finish inside
the frame.
3. First fit washers “B” onto the bolt threads from the outside.
4. Then screw nuts “C” onto the bolt threads and fasten them.
Working direction
A
B
C
A
B
C