11.4 Installation and repair of optional accessories

11.4.1 Fitting attachment hose reels to the frame

Attachment hose reels usually come prefitted and do not need to be removed unless the

complete hose reel is to be exchanged.

A retrofit kit is available and it contains all the necessary fasteners.

The hose reels differ depending on which side they are to be fitted (left or right). Be sure to

fit the hose reels to the correct side. The hoses should be pulled out in the working direction

from the bottom of the reel.

11.4.2 Hydraulic connection of attachment hose reels with hoses

The hydraulic connection of the attachment hose reels is established in the same way as for

hoses connected directly to the connecting block or valve block of the hydraulic unit.

For instructions on how to connect the hose lines, refer to the procedure described under

“Direct connection” in the “Repairs” chapter

Procedure for fitting an attachment hose reel:

1. Place the carrier plate on the unit frame in such a way that the holes in the carrier plate

are aligned with the holes in the frame.

2. Fit the supplied bolts “A” through the frame and the plate. The bolt head must finish inside

the frame.

3. First fit washers “B” onto the bolt threads from the outside.

4. Then screw nuts “C” onto the bolt threads and fasten them.

Working direction

A

B

C

A

B

C