Infinity supported application 9 – AEM Infinity Supported Applications - Honda H-Series Engine User Manual
Page 9

Infinity Supported Application
9
© 2014 AEM Performance Electronics
Infinity
Pin
Hardware Reference
7100-XXXX-62
7101-XXXX-63
Function
Dest.
Pin
Honda
OBD 1
Dest.
Pin
Honda
OBD
2a
Dest.
Pin
Honda
OBD
2b
Hardware
Specification
Notes
C1-43
HighsideSwitch_1
HS1 (switched 12V)
0.7A max, High
Side Solid State
Relay
See Setup Wizard page
'HighSide Assigment Tables'
f or conf iguration options.
See 2D lookup table
'HS1_Table' f or activ ation
settings.
C1-44
HighsideSwitch_0
VTEC
A4
A8
B12
0.7A max, High
Side Solid State
Relay
See Setup Wizard page
'HighSide Assigment Tables'
f or conf iguration options.
See 2D lookup table
'HS0_Table' f or activ ation
settings.
See Setup Wizard page
'VTEC' f or def ault activ ation
criteria.
C1-45
Crankshaf t Position Sensor
VR+
Crankshaf t
Position Sensor VR
+
B16
C12
C9
Dif f erential
Variable
Reluctance Zero
Cross Detection
See Setup Wizard page Cam/
Crank f or options.
C1-46
Crankshaf t Position Sensor
VR-
Crankshaf t
Position Sensor
VR-
B15
C2
C8
See Setup Wizard page Cam/
Crank f or options.
C1-47
Camshaf t Position Sensor 1
VR-
Camshaf t Position
Sensor 1 VR-
B11
C4
C29
Dif f erential
Variable
Reluctance Zero
Cross Detection
See Setup Wizard page Cam/
Crank f or options.
C1-48
Camshaf t Position Sensor 1
VR+
Camshaf t Position
Sensor 1 VR+
B12
C14
C30
See Setup Wizard page Cam/
Crank f or options.
C1-49
VR+_In_2
Non Driv en Lef t
Wheel Speed
Sensor +
Dif f erential
Variable
Reluctance Zero
Cross Detection
See Non Driv en Wheel
Speed Calibration in the
Setup Wizard Input Function
Assignment page.
C1-50
VR-_In_2
Non Driv en Lef t
Wheel Speed
Sensor -
C1-51
VR-_In_3
Driv en Lef t Wheel
Speed Sensor -
Dif f erential
Variable
Reluctance Zero
Cross Detection
See Driv en Wheel Speed
Calibration in the Setup
Wizard Input Function
Assignment page.
C1-52
VR+_In_3
Driv en Lef t Wheel
Speed Sensor +
C1-53
DBW1 Motor -
DBW Motor Control
Close
5.0A max
Throttle Control
Hbridge Driv e
+12V to close
C1-54
DBW1 Motor +
DBW Motor Control
Open
5.0A max
Throttle Control
Hbridge Driv e
+12V to open
C1-55
Power Ground
Ground
A24
A23
B10
Power Ground
Connect directly to battery
ground.
C1-56
Injector 6
Injector 6
Saturated or
peak and hold,
3A max
continuous
Injector 6
C1-57
Injector 5
Injector 5
Saturated or
peak and hold,
3A max
continuous
Injector 5