AEM Infinity Supported Applications - Honda H-Series Engine User Manual
Page 12

12
© 2014 AEM Performance Electronics
Infinity
Pin
Hardware Reference
7100-XXXX-62
7101-XXXX-63
Function
Dest.
Pin
Honda
OBD 1
Dest.
Pin
Honda
OBD
2a
Dest.
Pin
Honda
OBD
2b
Hardware
Specification
Notes
C2-12
Analog_In_17
A/C Analog
Request
12 bit A/D, 100K
pullup to 5V
0–5V analog signal. Use +5V
Out pins as power supply
and Sensor Ground pins as
the low ref erence. Do not
connect signals ref erenced
to +12V as this can
permanently damage the
ECU. See Setup Wizard
Input Functions page f or
input selection. See
AC_Request_In 1-axis table
f or activ ation logic.
C2-13
Analog_In_18
DBW_APP1 [%]
12 bit A/D, 100K
pullup to 5V
0–5V analog signal. Use +5V
Out pins as power supply
and Sensor Ground pins as
the low ref erence. Do not
connect signals ref erenced
to +12V as this can
permanently damage the
ECU.
C2-14
Analog_In_19
DBW_APP2 [%]
12 bit A/D, 100K
pullup to 5V
0–5V analog signal. Use +5V
Out pins as power supply
and Sensor Ground pins as
the low ref erence. Do not
connect signals ref erenced
to +12V as this can
permanently damage the
ECU.
C2-15
Analog_In_Temp_4
Charge Out
Temperature
12 bit A/D,
2.49K pullup to
5V
See ChargeOutTemp [C]
table f or calibration data and
ChargeOutTemp [C] f or
channel data.
C2-16
Analog_In_Temp_5
Airbox Temperature
12 bit A/D,
2.49K pullup to
5V
See AirboxTemp [C] table f or
calibration data and
AirboxTemp [C] f or channel
data.
C2-17
Analog_In_Temp_6
Fuel Temperature
12 bit A/D,
2.49K pullup to
5V
See FuelTemp [C] table f or
calibration data and
FuelTemp [C] f or channel
data.
C2-18
Analog_In_13
Oil Pressure
12 bit A/D, 100K
pullup to 5V
0–5V analog signal. Use +5V
Out pins as power supply
and Sensor Ground pins as
the low ref erence. Do not
connect signals ref erenced
to +12V as this can
permanently damage the
ECU. See Setup Wizard Oil
Pressure page f or setup
options. See OilPressure