Infinity supported application 15 – AEM Infinity Supported Applications - Honda H-Series Engine User Manual
Page 15

Infinity Supported Application
15
© 2014 AEM Performance Electronics
Infinity
Pin
Hardware Reference
7100-XXXX-62
7101-XXXX-63
Function
Dest.
Pin
Honda
OBD 1
Dest.
Pin
Honda
OBD
2a
Dest.
Pin
Honda
OBD
2b
Hardware
Specification
Notes
C2-37
Digital_In_6
Spare Digital Input
B5
C5
A27
No pullup. Will
work with TTL
signals.
Input can be assigned to
dif f erent pins. See Setup
Wizard page Input Function
Assignments f or input
mapping options.
C2-38
Digital_In_7
Clutch Switch
No pullup. Will
work with TTL
signals.
See ClutchSwitch 1-axis
table f or setup options. Input
can be assigned to dif f erent
pins. See Setup Wizard page
Input Function Assignments
f or input mapping options.
C2-39
Power Ground
Ground
Power Ground
Connect directly to battery
ground.
C2-40
Power Ground
Ground
Power Ground
Connect directly to battery
ground.
C2-41
CanH_Bout
CANH
Dedicated High
Speed CAN
Transceiv er
Not used
C2-42
CanL_Bout
CANL
Dedicated High
Speed CAN
Transceiv er
Not used
C2-43
LowsideSwitch_8
Engine Protect
Warning Out
Lowside switch,
4A max with
internal f ly back
diode. Inductiv e
load should NOT
hav e f ull time
power.
Activ ates if any of the
f ollowing f lags are true:
OilPressProtectOut,
LeanProtectOut,
CoolantProtect. Output can
be assigned to other
f unctions. See Setup Wizard
page LowSide Assignment
Tables f or additional options.
C2-44
LowsideSwitch_7
Spare GPO1
Lowside switch,
4A max with
internal f ly back
diode. Inductiv e
load should NOT
hav e f ull time
power.
See Spare GPO1 Basic
Setup section of User GPIOs
and PWM Setup Wizard page
LowSide Assignment Tables
f or additional options.
C2-45
UEGO 2 VM
UEGO 2 VM
Bosch UEGO
Controller
Virtual Ground signal.
Connect to pin 5 of Bosch
UEGO sensor.
C2-46
UEGO 2 UN
UEGO 2 UN
Nernst Voltage signal.
Connect to pin 1 of Bosch
UEGO sensor
C2-47
UEGO 2 IP
UEGO 2 IP
Pumping Current signal.
Connect to pin 6 of Bosch
UEGO sensor
C2-48
UEGO 2 IA
UEGO 2 IA
Trim Current signal. Connect
to pin 2 of Bosch UEGO
sensor
C2-49
UEGO 2 HEAT
UEGO 2 HEAT
Lowside switch f or UEGO
heater control. Connect to
pin 4 of Bosch UEGO
sensor. NOTE that pin 3 of
the Sensor is heater (+) and
must be power by a f used/
switched 12V supply .