AEM Infinity Supported Applications - Honda H-Series Engine User Manual
Page 8

8
© 2014 AEM Performance Electronics
Infinity
Pin
Hardware Reference
7100-XXXX-62
7101-XXXX-63
Function
Dest.
Pin
Honda
OBD 1
Dest.
Pin
Honda
OBD
2a
Dest.
Pin
Honda
OBD
2b
Hardware
Specification
Notes
C1-37
Analog_In_9
Fuel Pressure
12 bit A/D, 100K
pullup to 5V
0–5V analog signal. Use +5V
Out pins as power supply
and Sensor Ground pins as
the low ref erence. Do not
connect signals ref erenced
to +12V as this can
permanently damage the
ECU. See the Setup Wizard
Fuel Pressure page f or setup
and calibration. Monitor the
FuelPressure [psig] channel.
C1-38
Analog_In_10
Baro Sensor
12 bit A/D, 100K
pullup to 5V
0–5V analog signal. Use +5V
Out pins as power supply
and Sensor Ground pins as
the low ref erence. Do not
connect signals ref erenced
to +12V as this can
permanently damage the
ECU. See the Setup Wizard
Barometric Pressure page f or
setup and calibration. Monitor
the BaroPress [kPa] channel.
C1-39
Analog_In_11
Shif t Switch Input
12 bit A/D, 100K
pullup to 5V
0–5V analog signal. Use +5V
Out pins as power supply
and Sensor Ground pins as
the low ref erence. Do not
connect signals ref erenced
to +12V as this can
permanently damage the
ECU.
See the 1D lookup table
'Shif tSwitch' f or setup. Also
assignable to multiple
f unctions. See Setup Wizard
f or details.
C1-40
Analog_In_12
Mode Switch
12 bit A/D, 100K
pullup to 5V
0–5V analog signal. Use +5V
Out pins as power supply
and Sensor Ground pins as
the low ref erence. Do not
connect signals ref erenced
to +12V as this can
permanently damage the
ECU.
See the 1D lookup table
'ModeSwitch' f or input state.
A multi-position rotary switch
such as AEM P/N 30-2056 is
recommended. Also
assignable to multiple
f unctions. See Setup Wizard
f or details.
C1-41
+5V_Out_1
+5V Out
D19
D10
C19
Regulated,
f used +5V
supply f or
sensor power
Analog sensor power
C1-42
+5V_Out_1
+5V Out
D20
D4
C28
Regulated,
f used +5V
supply f or
sensor power