Motor ground / primary power – Class1 EZFill Foam Refill User Manual
Page 16
❑ Installation
16
EZFill Installer / User Guide, p/n: 029-0020-82-0
If an additional harness extension is required, contact Class1 at
352-629-5020.
The power must be fused for 12VDC (or optional 24VDC), minimum 20
amp. circuit to meet NFPA specifications.
IMPORTANT !
DO NOT CONNECT POWER SUPPLY HARNESS TO A “LOAD SHEDDING SYS-
TEM.”
Motor Ground / Primary Power
CAUTION !
PREVENT CORROSION OF POWER AND GROUND CONNECTIONS BY SEAL-
ING THESE CONNECTIONS WITH SILICONE SEALANT.
DO NOT CONNECT THE MAIN POWER LEAD TO SMALL LEADS THAT ARE
SUPPLYING SOME OTHER DEVICE, SUCH AS A LIGHT BAR OR SIREN. THE
CLASS1 EZFILL FOAM REFILL SYSTEM REQUIRES 40 AMP MINIMUM CUR-
RENT.
USE MINIMUM 14 AWG TYPE SXL/GXL WIRE.
Primary electrical power must be supplied directly from the battery, the bat-
tery master disconnect switch or solenoids to the Hale EZFill refill system.
The primary power connection must be made so that power is supplied to
the EZFill system when the main apparatus electrical system is energized.
Be sure the EZFill system is grounded to the chassis.
When making the ground connections make sure lugs are soldered to the
strap ends for trouble free connections. Seal all connection against
corrosion.