9. WALLWALKER
9
This section covers the removal,
inspection, and assembly of the
WallWalker
®
and guard flap.
9.1
Inspect WallWalker
®
tip.
A If the tip is worn, as shown, replace.
9.2
Remove crankcase screws and wave
washers.
9.3
Remove WallWalker
®
from saw.
NOTE: On late model saws it is
necessary to remove the bar
plate prior to removing the
crankcase screws.
9.4
Remove guard flap screws and
washer.
9.5
Remove and inspect guard flap.
A Replace the flap if it is torn or
damaged in any way.