Replacing a copper or fiber optic module, Removing a copper or fiber optic module, Figure 16 unlocking the bail latch – Brocade Communications Systems Brocade ICX 6650 53-1002599-01 User Manual
Page 55: Figure 16, Unlocking the bail

Brocade ICX 6650 Hardware Installation Guide
39
53-1002599-01
Replacing a copper or fiber optic module
5
Replacing a copper or fiber optic module
You can remove an SFP+ or QSFP+ transceiver from a slot and replace it with a new one while the
Brocade ICX 6650 is powered on and running.
This section provides information about the following tasks:
•
Removing a copper or fiber optic module
•
Installing a new copper or fiber optic module
•
Cabling a fiber optic module
Removing a copper or fiber optic module
You can remove a copper or fiber SFP, SFP+, or QSFP+ transceiver from a slot while the Brocade
ICX 6650 is powered on and running.
While removing a copper or fiber optic module, be sure to wear an ESD wrist strap with a plug that
can be inserted in the ESD connector on the Brocade ICX 6650.
CAUTION
For safety reasons, the ESD wrist strap should contain a series 1 megohm resistor.
To remove a copper or fiber optic module from an SFP slot, do the following.
1. Put on the ESD wrist strap and ground yourself by attaching the clip end to a metal surface
(such as an equipment rack).
2. Disconnect the copper or
fiber cable connector from the port connector.
3. Unlock the copper or
fiber optic module by pulling the bail latch forward, away from the front
panel of the module.
On 1000BaseSX ports, the bail latch is enclosed in a black sleeve, and on 1000BaseLX ports,
the bail latch is enclosed in a blue sleeve.
FIGURE 16
Unlocking the bail latch
NOTE
The bail latch may be attached to either the top or the bottom of the mini-GBIC.
1
Bail Latch
1