Chapter
5
Managing the Brocade ICX 6650
In this chapter
•
•
•
Displaying Brocade ICX 6650 CPU usage . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
•
Hardware maintenance schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
•
Replacing a copper or fiber optic module . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
•
FRU removal and replacement procedures . . . . . . . . . . . . . . . . . . . . . . . . . . 40
•
•
CAUTION
The procedures in this chapter are for qualified service personnel.
Managing temperature settings
The device contains temperature sensors that the software reads based on a configurable device
poll time. To protect the device from overheating, the following temperature threshold levels exist:
•
The warning level is the temperature at which the device generates a Syslog message and
SNMP trap. It is configurable.
•
The shutdown level is the temperature at which the device reboots. It is set by the device and is
not configurable.
The fan speed settings are set by the device, and are not configurable.