beautypg.com

Service (cont.) – Bunn G9-2T DBC User Manual

Page 52

background image

52

SERVICE (Cont.)

Membrane Switches (Model MHG only)

Location:

The membrane switch is located on the front of the

hopper housing.

Test Procedure:

1. Press and hold the right hidden button to enter

programming.

2. Scroll through the menus to Service Tools and

select YES.

3. Select YES at Test Outputs and scroll through to

Test Switches by pressing NEXT.

4. Follow the chart below to test all switches.

If any of the switches indicate a fault, replace the

membrane switch.

FIG 57 MEMBRANE SWITCH

PRESSING ANY BUTTON

EXCEPT THE RIGHT HIDDEN

BUTTON WILL DISPLAY

THE BUTTON NAME

ON THE SCREEN

TEST SWITCHES?

NO YES

PRESS RIGHT

HIDDEN TO EXIT

NOTHING PRESSED

TEST FREQUENCY?

NO YES

Removal and Replacement

1. Disconnect the grinder from the power supply.

2. Remove the rear access panel.

3. Disconnect the membrane switch harness from the

control board.

4. Carefully peel the membrane switch from the front

of the switch bezel.

5. Remove any excess adhesive from the bezel sur-

face.

6. Remove the backing from the new membrane

switch.

7. Feed the membrane switch harness through the

openning and apply the new membrane switch to

the switch bezel.

8. Connect the switch harness to J9 on the display

board.

41545 122209