beautypg.com

Service (cont.) – Bunn G9-2T DBC User Manual

Page 31

background image

31

SERVICE (Cont.)

Circuit Breaker (Models LPG, LPG-2E, FPG, FPG-2 DBC)

P1036

FIG. 22 CIRCUIT BREAKER

P1037

FIG. 23 CIRCUIT BREAKER TERMINALS

RED from Motor-LPG-2E

BLK from Start Switch-LPG

BLK from Power Cord

Removal and Replacement:

1. Remove the wires from the circuit breaker.

2. Remove the face nut securing circuit breaker to the

motor support.

3. Remove circuit breaker.

4. Install new circuit breaker in motor support and

secure with face nut.

5. Reconnect the wires.

6. Refer to FIG. 23 when reconnecting the wires.

Location:

The circuit breaker is located on the rear of the

grinder next to the power cord strain relief bushing. The

circuit breaker is not available on Model LPG equipped

with capacitor.

Test Procedure:

1. Disconnect grinder from the power source.

2. Remove the wires from the circuit breaker.

3. Check for continuity between the terminals. Conti-

nuity must be present between the terminals.

If continuity is present as described the circuit breaker

is functioning properly.

If continuity is not present as described, press reset

button and repeat step #3, if continuity is not present

as described, replace the circuit breaker.

41545 122209