SERVICE (Cont.)

DECHAFFER (Models LPG & FPG)

FIG. 13 DECHAFFER

P1062

Location:

The dechaffer spring plates are located in the burr

housing cap.

1

FIG. 14 DECHAFFER REMOVAL/REPLACEMENT

P1063

2

Removal and Replacement: Refer to Fig. 14

1. Remove coffee beans from hopper(s).

2. Lay grinder on it’s back.

3. Remove the #4-40 truss head screw securing

dechaffer support (1) to the burr housing cap.

4. Remove dechaffer support (1).

5. Remove dechaffer spring plate (2) from burr hosing

cap.

6. For models with extra fine dechaffer, remove dechaf-

fer support (3).

7 Place new dechaffer spring plate (2) in the slot in

the burr housing cap.

8. Place dechaffer support (1) over dechaffer spring

plate (2), support (3) and secure with a #4-40 truss

head screw.

OPTONAL EXTRA

FINE DECHAFFER

3 2 1

41545 122209