beautypg.com

Bunn G9-2T DBC User Manual

Page 19

background image

19

SERVICE (Cont.)

DC MOTOR AND GRIND CHAMBER - G1MD ONLY

FIG. 6 DC MOTOR AND GRIND CHAMBER

P1706

Location:

The motor is located inside the upper part of the grinder

housing.

Test Procedures:

1. Remove the rear panel. Press the red “Reset”

button visible on the rear of the motor. Listen care-

fully for a “click”. This resets the motor protection

circuit and may indicate that something other than

coffee was inserted into the hopper for grinding.

If the grinder remains unable to start, proceed to #2.

If the grinder stops operating shortly after starting, refer

to removal and replacement instructions and inspect

for foreign materials.

2. Disconnect the grinder from the power source and

place a coffee bag behind the dispense chute.

3. Remove the black wire from the rectifier (+) ter-

minal and the red wire from the (-) terminal.

4. Check the voltage across the (+) and (-) terminals

with a voltmeter. Connect the grinder to the power

source. When the Off/On/Start switch is momen-

tarily placed in the “START” (lower) position and

then left in the “ON” (center) position and a bag

is in place behind the coffee dispense chute. The

indication must be approximately 108 volts dc.

5. Disconnect the grinder from the power source.

If voltage is present as described replace the motor.

If voltage is not present as described, reconnect the

white or red and white/blue wires to the motor, refer

to the Wiring Diagrams and check the grinder wiring

harness.

Removal and Replacement - Motor (Refer to Fig. 8)

1. Disconnect all wires from the motor.

2. Remove the two .250”-20 screws (1) securing

grind selector dial plate and grind selector knob

(2) to the grind chamber. Remove dial plate and

selector knob as an assembly.

3. Slide burr (7), auger rotor/spring assembly (3) and

burr rotor disc (4) off the grinder motor shaft as

an assembly.

4. Remove the two .250”-20 screws (8) securing the

stationary burr (9) to the grind chamber.

5. Remove bushing (10) and washer (11) from the

grinder motor shaft.

6. Remove the two #8 thread forming screws (12)

securing the fill plate (13) to grinder housing and

remove plate (13).

7. Remove the four #10-24 screws (14) securing the

chute assembly (15) to the grind chamber and

remove chute assembly (15).

8. Disconnect all the wires from the rectifier (23).

9. Remove the four .312”-18 screws (20), rubber

washers (22) and flat washers (21) securing

the motor and bracket to the grinder housing

bracket.

41545 122209

This manual is related to the following products: