SERVICE (Cont.)

Timer (Model LPG-2E)

P1061

Location:

The timer is located inside the hopper housing just

behind the left solenoid.

Test Procedure:

1. Disconnect grinder from the power source.

2. Insert the leads of a voltmeter set to read at least

120 volts AC, along side the red wire (terminal 8)

and the white wire (terminal 2) of the harness plug.

Place the Off/On/Start switch in the “ON” center

position. Connect the grinder to the power source.

The indication must be 120 volts AC.

3. Disconnect the grinder from the power source.

If voltage is present as described, proceed to step

#4.

If voltage is not present as described, refer to the wiring

diagram and check the grinder wiring harness.

4. Place the hopper selector switch in the left posi-

tion.

5. Insert the leads of a voltmeter set to read at least

120 volts AC, along side the red wire (terminal 8)

and the orange wire (terminal 10) of the harness

plug. Place the Off/On/Start switch in the “START”

lower position. Connect the grinder to the power

source. The indication must be 120 volts AC for the

set gate time and return to 0 volts.

6. Disconnect the grinder from the power source.

FIG. 48 TIMER

If voltage is present as described, proceed to step

#7.

If voltage is not present as described, replace the

timer.

7. Place the hopper selector switch in the right posi-

tion.

8. Insert the leads of a voltmeter set to read at least

120 volts AC, along side the red wire (terminal 8)

and the violet wire (terminal 9) of the harness plug.

Place the Off/On/Start switch in the “START” lower

position. Connect the grinder to the power source.

The indication must be 120 volts AC for the set gate

time and return to 0 volts.

9. Disconnect the grinder from the power source.

If voltage is present as described, proceed to

step#10.

If voltage is not present as described, replace the

timer.

10. Insert the positive (+) lead of a volt meter set to read

at least 120 volts DC, along side the black wire (ter-

minal 7) of the harness plug and insert the negative

(-) lead along side the white/black wire (terminal 6)

of the harness plug. Place the Off/On/Start switch

in the “START” lower position. Connect the grinder

to the power source. The indication must be 120

volts DC for the set gate time plus clean out time

and return to 0 volts.

If voltage is present as described the timer is operating

properly.

If Voltage is not present as described, replace the

timer.

Removal and Replacement:

1. Disconnect the main wiring harness plug from the

terminal block on the timer.

2. Remove the two timer dial knobs located on the

rear panel of the grinder.

3. Remove nut and internal tooth lockwasher securing

dials to the rear panel.

4. Loosen the two #8-32 pan head screws securing

the timer and timer mounting bracket to the motor

support plate.

41545 122209