background image

4. Remove 2 screws from blower access door and remove blower

access door.

5. Disconnect blower leads from furnace control. Record wire

color and location for reassembly. All other factory wires can
be left connected, but field thermostat connections may need
to be disconnected depending on their length and routing.

6. Remove 2 screws holding control box to blower shelf.

7. Hang control box from front of furnace casing and away from

blower compartment.

8. Remove 2 screws holding blower assembly to blower deck

and slide blower assembly out of furnace.

9. Clean blower wheel and motor using a vacuum with soft brush

attachment. Blower wheel blades may be cleaned with a small
paint or flux brush. Do not remove or disturb balance weights
(clips) on blower wheel blades.

10. Vacuum any loose dust from blower housing, wheel and

motor.

Table 12—Orifice Size* And Manifold Pressure For Gas Input Rate (Continued)

(Tabulated Data Based On 22,000 Btuh Per Burner, Derated 4 Percent For Each 1000 Ft Above Sea Level)

ALTITUDE

RANGE

(FT)

AVG GAS

HEAT VALUE

AT ALTITUDE

(BTU/CU FT)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

U.S.A.

Only

5001

to

6000

725

43

3.4

43

3.5

43

3.6

43

3.7

750

43

3.2

43

3.3

43

3.4

43

3.5

775

43

3.0

43

3.1

43

3.2

43

3.3

800

43

2.8

43

2.9

43

3.0

43

3.1

825

43

2.6

43

2.7

43

2.8

43

2.9

850

43

2.5

43

2.5

43

2.6

43

2.7

875

43

2.3

43

2.4

43

2.5

43

2.6

900

43

2.2

43

2.3

43

2.3

43

2.4

ALTITUDE

RANGE

(FT)

AVG GAS

HEAT VALUE

AT ALTITUDE

(BTU/CU FT)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

U.S.A.

Only

6001

to

7000

675

43

3.4

43

3.5

43

3.6

43

3.7

700

43

3.1

43

3.3

43

3.4

43

3.5

725

43

2.9

43

3.0

43

3.1

43

3.2

750

43

2.7

43

2.8

43

2.9

43

3.0

775

43

2.6

43

2.7

43

2.7

43

2.8

800

43

2.4

43

2.5

43

2.6

43

2.7

825

43

2.3

43

2.3

43

2.4

43

2.5

850

43

2.1

43

2.2

43

2.3

43

2.4

ALTITUDE

RANGE

(FT)

AVG GAS

HEAT VALUE

AT ALTITUDE

(BTU/CU FT)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

U.S.A.

Only

7001

to

8000

650

43

3.1

43

3.2

43

3.4

43

3.5

675

43

2.9

43

3.0

43

3.1

43

3.2

700

43

2.7

43

2.8

43

2.9

43

3.0

725

43

2.5

43

2.6

43

2.7

43

2.8

750

43

2.4

43

2.4

43

2.5

43

2.6

775

43

2.2

43

2.3

43

2.4

43

2.4

800

43

2.1

43

2.1

43

2.2

43

2.3

825

48

3.7

43

2.0

43

2.1

43

2.2

ALTITUDE

RANGE

(FT)

AVG GAS

HEAT VALUE

AT ALTITUDE

(BTU/CU FT)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

Orifice

No.

Manifold

Pressure

U.S.A.

Only

8001

to

9000

625

43

2.9

43

3.0

43

3.1

43

3.2

650

43

2.7

43

2.8

43

2.9

43

3.0

675

43

2.5

43

2.6

43

2.7

43

2.8

700

43

2.3

43

2.4

43

2.5

43

2.6

725

43

2.2

43

2.2

43

2.3

43

2.4

750

43

2.0

43

2.1

43

2.2

43

2.2

775

48

3.6

48

3.7

43

2.0

43

2.1

* Orifice numbers 43 are factory installed

39