Wood floor application
Use the wooden screws provided, see overview diagram
Use the screws in the screws set".
q Drill pilot holes:
1
/
8
" (3 mm) for the (5 x 60 mm) wooden screws
5
/
64
" (2 mm) for the (4 x 15 mm) wooden screws
Being certain the screws penetrate through
the flooring and into the wall plate a minimum
of
3
/
4
" (19 mm).
q Attach the antiĆtipĆbracket completely. Be sure
screws hold tight.
i
The distance
D between the antiĆtipĆbrackets is
adequately the width of the appliance.
Concrete floor applications
d
CAUTION
d
Always wear safety glasses and other necessary
protective devices or apparel when installing or
working with anchors ć risk of injury!
Not recommended for use in lightĆweight masonry
material such as block or brick.
Not recommended for use in new concrete which has
not had time to cure.
Do not use core drills to drill holes for this anchor.
Use concrete anchor M8 and M8 srew. Additional use
the wooden screws provided, see overview diagram
Use the screws in the screws set".
q Drill a 10 mm diameter hole any depth exceeding
the minimum embedment. Use the provided drill.
q Clean hole or continue drilling additional depth.
q Manually insert the screw into the wall plug until the
screw begins to resist.
q Knock the wall plug and screw into the hole until the
screw head is approx. ½" (13 mm) from the antiĆtip
bracket.
i
The distance
D between the antiĆtipĆbrackets is
adequately the width of the appliance.
6. Attaching an alternative antiĆtip
device
!
IMPORTANT NOTE
!
If possible, always screw the wooden beam to
existing studs on the rear panel of the cavity.
If the antiĆtip brackets cannot be attached securely,
an alternative antiĆtip device can be attached.
However, ensure that there is no play between the
appliance and the antiĆtip device.