15. Service

Image 15-7

I2C Diagnostics

Device

Slave address

Lamp driver

I2C Diagnostics

0x78

Lamp Eeprom

0xA0

Power Supply

0x30

I2C Mulitplexer

0xE0

Red Formatter

0x34

Green Formatter

0x36

Blue Formatter

0x38

Motor driver

0x1A

Image 15-8

15.4.2 Lamps and power supply

What can be done ?

This menu item gives an overview of the lamp and power supply errors.

How to display the overview menu ?

1. Press MENU to activate the menu bar.

2. Press to select the Service item. (image 15-9)

3. Press to pull down the Service menu.

4. Use or to select Diagnostics.

5. Press to pull down the menu.

6. Use or to select Lamps and power supply.

7. Press ENTER to select Lamps and power supply.

A text box with errors is displayed. (image 15-10)