Toshiba Magnia 7100 User Manual
Page 79
67
HW Diagnostics
SAF-TE TEST
SAF-TE LED Reset (No Error Flag)
Hit any key
When the message above is displayed, check that all LEDs of the hard disk drives switch
off. Press the
SAF-TE TEST (SAF) Error log
Status
Error name
Meaning
01
SAF-TE TEST ERROR
SAF-TE controller has not been detected.
[12. SMC TEST]
To test the SMC functions and the LED display functions.
[01. Self&Sensor test]
The self and sensor test for each controller is performed with the results displayed.
[02. Front Panel test]
Verifies the functions of LED, LCD panel. Check that:
LED test:
Please check LED all GREEN.
OK (Y) / FAILED (N)
Please check LED all ORANGE.
OK (Y) / FAILED (N)
Please check LED all OFF.
OK (Y) / FAILED (N)
Please check HddFaultLED ON.
OK (Y) / FAILED (N)
LCD test:
Please check LCD all ON.
OK (Y) / FAILED (N)
Please check LCD all OFF.
OK (Y) / FAILED (N)