Toshiba Magnia 7100 User Manual
Page 78

66
HW Diagnostics
CD-ROM TEST
[10. CD-ROM TEST]
To test the computer's CD-ROM functions,
insert the SST CD-ROM for the test.
[01. Sequential address Read]
This subtest is a sequential reading of one block unit of all the logical addresses.
[02. Random Address Read]
This subtest reads data at random addresses.
For the error log information, refer to [Log Utilities] of SCSI HDD TEST.
[11. SAF-TE TEST]
To check the SAF-TE function and the status LED of the hard disk drives.
[01. SAF-TE test]
The SAF-TE test detects the SAF-TE controller and checks its operation by flashing the
LED for each hard disk drive.
The test first detects the SAF-TE controller and shows the connecting destination of the
detected SAF-TE controller (host number, SCSI ID, and channel number) with model name.
--HT—ID----CH--VENDOR—PRODUCT-------FAN—PS--SLOT
XX XX XX XXXXX
XXXX
XX XX XX
After detecting the SAF-TE controller, the following message is displayed:
SAF-TE LED Steady ON (Faulty Flag)
Hit any key
When the message above is displayed, check that all LEDs of the hard disk drives are lit
(orange). Press the
SAF-TE LED Blinking (Rebuilding Flag)
Hit any key
When the message above is displayed, check that all LEDs of the hard disk drives are
flashing (orange). Press the
SAF-TE LED Steady ON (Rebuild Interrupted) Hit any key
When the message above is displayed, check that all LEDs of the hard disk drives are lit
(orange). Press the
SAF-TE LED Flashing (Rebuilding Flag)
Hit any key
When the message above is displayed, check that all LEDs of the hard disk drives are
flashing (orange). Press the