Toshiba Magnia 3200 User Manual
Page 109
Setting of transmitting Trap to Insight Manager screen
If a fault occurs in a server, it is possible to transmit a SNMP trap to a Compaq Insight
Manager.
Insigh
Item
tManager Setting screen
Explanation
[Trap is transmitted to
If this checkbox is checked, Traps are sent to InsightManager.
InsightManager]
check box
-Event Level-
Selects the level of the event transmitted to InsightManager
[Error only] radio
button
Only sends a trap after an error occurs.
[Warning or more]
radio button
Sends a trap after a waring or an error on the machine.
[Set] button
Activates the settings.
Notice In case you use this function, please keep the following conditions.
- The S
needed i
.E.L. function and the Configure Alerts function of the HEW Agent are
n a server. If these functions of HEW are not installed, please install them.
n, you need to specify the following setting.
nt Type : Error or Warning, Event Source :
- You need to specify the Trap destinations of SNMP Service. In the machine that
select the “Traps” tab. In this screen, please specify the IP address of the machine
ap destination.
Guide of the Insight Manager for using Insight Manager.
- In the Configure Alerts scree
Logfile : Application, Eve
“HEWSEL,HEWMB”
installed an Agent function of HEW, please open the SNMP Service Properties, and
that installed Insight Manager as a Tr
Please refer to the User's
99