XC 701P41810 (EFI Part Number: 45042719)

Restore Backup

The Windows NT OS Workstation software resides on the hard disk and is backed up the
first time you turn on the Fiery EX12. If necessary, you can retrieve a backup of the
software using the Fiery Restore/Update CD. Insert the CD in the CD drive, and restart
the Fiery EX12. After restoring, you will need to reinstall any features and utilities you have
installed from the User Software CD and the User Documentation CD.

Fiery EX12 passwords

The Fiery EX12 password used to access Setup, as well as the password required to log in to
the Fiery EX12, are case sensitive and must be entered

exactly

.

Maximum number of users for SMB

Windows NT 4.0 supports a total of 10 SMB simultaneous connections, including the
Direct connection, Print queue, and Hold queue.

Windows 2000 and LPR availability

When you perform a fresh install of Windows 2000 on a client computer, no LPR services
are available by default. Your only option is to print through a standard TCP/IP port or use
SMB printing. However, if you converted a Windows NT 4.0 computer to Windows 2000,
LPR printing services are retained.

Fiery EX12 domain configuration

To add the Fiery EX12 to a domain in configurations that do not include the Fiery
Advanced Controller Interface (FACI) option, you must add the Fiery EX12 from another
Windows NT 4.0 server on the network, using the Server Manager utility.

Tray Alignment

Tray Alignment is not an option that can be set from the Fiery LCD display. Use
Command Workstation to set the Tray Alignment option.

Diagnostics

E-mail must be set to “on” to test the machine diagnostics. If E-mail is switched to “off ”,
the LCD will remain blank when you run diagnostics.

Startup error—driver failed

You may see the following message on the monitor when you restart the system: “At least
one service or driver failed during system startup. Use Event Viewer to examine the event
log for details.” Ignore the message and click OK to close the window.

Memory configuration

The total memory is 256MB. The server monitor during startup displays 120MB.
The Command Workstation memory usage bar displays 136MB.

Command WorkStation connection lost

If the message “Connection to the Fiery EX12 lost” appears in the Command WorkStation
window, click OK and then restart the Fiery EX12 using Reboot System from the Server
menu on the Control Panel. You can then start Command WorkStation to re-establish
the connection.