Printing groups, Colorwise pro tools – Xerox Stampante DocuColor 12 con Fiery EX12-14994 User Manual

Page 15

background image

Page 15

XC 701P41810 (EFI Part Number: 45042719)

Keep Original

Avoid setting the Keep Original option to use the HotFolder as the repository.

Server association

The Hot Folder interface used to find and associate print servers to folders differs slightly
from other Fiery tools. When a new Hot Folder is added, you need to search for the server
you want to use for printing.

Passwords

Passwords can be up to 31 characters long. Passwords are case sensitive.

For security, passwords are hidden when you enter them.

The password is included in a print job as an unencrypted string, which can be intercepted
with a network sniffer, and viewed by opening the contents of the PostScript file.

The list of passwords on the Fiery EX12 is not encrypted.

Group names

Group names can be up to 16 characters long.

Incorrect group name or password

If you enter an incorrect group name or password for a print job, the job generates an error
message and proceeds to the Printed Jobs queue without printing.

Using other printer drivers

If you do not use the Fiery EX12 printer driver to send the print job, you need to enter the
group name and password in Command WorkStation or Fiery WebSpooler.

Job Log fields

The Notes field in the printer driver is stored in the Notes 1 field in the Job Log. The
Group Name field in the printer driver is stored in the Notes 2 field in the Job Log.

Output profiles

If you use the output profile Fiery EX12 DocuColor 12 Max PPM K with the rendering
style Absolute Colorimetric, equal values of red, green, and blue retain CMYK values.
Jobs will be printed at the copier-rated engine speed for color pages, even if the job contains
black-only pages.

Serial port appears to be available while in use by the LCD

The Fiery EX12 COM2 serial port is used by the LCD screen by default, yet is still able to
be selected during the installation of other programs. Multiple selections of this port may
cause a conflict.

Calibration with a densitometer

You can calibrate the Fiery EX12 with an XRite DTP 32 or 41 densitometer via Client
Workstation or Server only if you have the Fiery Advanced Controller Interface option
installed. Otherwise, you must calibrate using the AutoCal

or ColorCal

method if you

are using the copying capabilities. For more information on calibration, see the
Color Guide.

Printing groups

ColorWise Pro
Tools