XC 701P41810 (EFI Part Number: 45042719)

Character limitation in Network Setup

In Network Setup from the Fiery EX12 Control Panel, you can enter a maximum of
32 characters for the context name. When using Fiery Setup

or Fiery WebSetup

, you

can enter more than 32 characters.

Remote Setup for Bindery and NDS

When configuring Bindery or NDS in Network Setup using WebSetup or EFI Command
WorkStation

from a client computer, enter a password in order to make changes. For

Bindery Setup, log in as Admin, Supervisor, or Guest, with the appropriate password.
For NDS, select the appropriate login and password.

WebSetup

During Bindery Setup, WebSetup only allows you to choose “Admin,” “Supervisor,” or
“Guest.” It does not allow you to enter a unique user name. If these accounts have been
renamed on your system, use local setup.

IPX Auto Frame Type

If you enable IPX Auto Frame Type in Setup, the Fiery EX12 will bind only to the first
frame type it finds, which is typically 802.2 or Ethernet II. To ensure that all available frame
types are bound, select each one individually. After the Fiery restarts upon exiting Setup,
print the Configuration page to verify that all selected frame types were successfully bound.

Point and Print Drivers

In Setup from the Fiery EX12 Control Panel, the Point and Print Drivers option follows
the Use Automatic Configuration option. The sequence of these options is incorrect in the

Configuration Guide

.

Point and Print on Windows2000/XP computers

Point and Print (PnP) printing is not supported from Windows2000/XP computers.
Printer drivers should be installed from the User Software CD or WebTools

.

For information on installing these drivers, see Chapter 1 of the

User Software

Installation Guide

.

WINS Address

The WINS Address will not appear in WebSetup in DHCP mode when configuring the
Network Setup. Print a Configuration page to see the WINS address.

Fiery color calibration

DTP34 and the EFI Spectrometer

(ES-1000) are not supported for the Fiery EX12.

Creating an SMB port in Windows 2000/XP

To create an SMB port in Windows 2000/XP, you must first establish a connection to the
server with an IP address. Do this by choosing Start and then selecting Run. At the prompt,
enter “\\” followed by the server IP address, and then click OK. After you make the
connection, you can follow the instructions to create an SMB port on Windows 2000/XP.