3 both sides density adjustment, 1 [01 both sides max. dens. manual, Both sides density adjustment – Konica Minolta bizhub PRESS 2250P User Manual
Page 49: 01 both sides max. dens. manual] -3, 3both sides density adjustment
bizhub PRESS 2250P
3-3
3.1
[01 Both Sides Max. Dens. Manual]
3
3
Both Sides Density Adjustment
3.1
[01 Both Sides Max. Dens. Manual]
The machine consists of Main Body 1 and Main Body 2, each printing the front side or back side. As a result,
there may be a difference in the density of the 2 main bodies. To eliminate the difference, you need to output
and check the respective chart sheets in maximum density and then manually adjust the density.
Patterns of the charts
Pattern 1:
Prints 2 chart sheets in total, one from each main body, using the maximum density value manually set.
Pattern 2:
Prints 10 chart sheets in total, 5 from each of the two main bodies using the maximum density value set to -
5, -3, -1, +1, and +3, regardless of the manually set value.
Objects of adjustment: Main Body 1 (Side 1), Main Body 2(Side 2)
Adjustable range: - 5 to + 3
1
Press [Adjustment] on the Machine Screen to display the Adjustment Menu Screen.
2
Press [07 Both Sides Density Adjustment] and [01 Both Sides Max. Dens. Manual] in sequence.
The Both Sides Maximum Density Manual Adj. Screen will be displayed.
3
Press [Print Mode].
A dialog box will be displayed to select a pattern of chart to be printed.
4
Select [Pattern 1] or [Pattern 2].