beautypg.com

Rear view of the server – Lenovo ThinkServer RD530 User Manual

Page 33

background image

LED

Status

Description

Action

Solid off

The server is running at a normal
temperature.

2

Ambient temperature

limit LED

Solid on (amber)

The ambient temperature is below
7°C (44.6°F) or over 40°C (104°F).

Check the BMC for errors and
run the diagnostic programs. See
“Using a diagnostic program” on
page 140
.

Solid off

The system fans are operating
correctly.

3

System fan error LED

Solid on (amber)

One or more system fans are
running at low speed or have
been removed.

Check the BMC for errors and
run the diagnostic programs. See
“Using a diagnostic program” on
page 140
.
Note: To identify the failing
system fans, check the status
LEDs on the system board. See
“System board LEDs” on page
41.

Solid off

The memory modules
are operating at a normal
temperature.

4

Memory module

status LED

Solid on (amber)

One or more memory modules
are overheated.

Check the BMC for errors and
run the diagnostic programs. See
“Using a diagnostic program” on
page 140
.

Solid off

The microprocessors are
operating at a normal
temperature.

5

Microprocessor

status LED (also known
as CPU error LED)

Solid on (amber)

One or more microprocessors are
overheated.

Check the BMC for errors and
run the diagnostic programs. See
“Using a diagnostic program” on
page 140
.

Rear view of the server

This topic provides information to help you locate the connectors and components on the rear of your server.

Chapter 3

.

Product overview

21