R81, c81 beverage regulators – Norgren U.L. Listed Beverage Regulators User Manual
Page 7
![background image](/manuals/467631/7/background.png)
R81, C81 Beverage Regulators
Littleton, CO USA
Phone 303-794-2611
Fax 303-795-9487
ALE-12-7
†
Outlet pressure can be adjusted to pressures in excess of, and less than, those specified. Do not use these units to control pressures outside of the specified ranges.
†† The listed check valves and manifolds with integral check valves are designed for use with Norgren R81 regulators and C81 regulator configurations. They are not
recommended for use with other regulators and regulator configurations unless separate pressure relief protection is provided in each of the outlet lines.
*
The 16-006-107 check and relief valve meets the pressure and flow requirements of paragraphs 4.5 and 4.6 of NSDA Pamphlet TD02, Installation and Operational
Procedures for Pressurized Soft Drink Dispensing Systems, dated July, 1980.
** Check valves, or manifolds with integral check valves, must be installed in the outlet ports of the wye when the wye is installed in the outlet port of the Norgren R81
regulator.
Ordering Information.
Models listed include integral relief valve with cracking pressure of 130 ± 4 psig (9.0 ± 0.28 bar), PTF threads,
relieving diaphragm, 5 to 100 psig (0.34 to 6.9 bar) outlet pressure adjustment range†. A gauge is not included.
Port
Model
Weight lb (kg)
1/4"
R81-200-LNKA
1.3 (0.59)
Alternative Models
-
A
N
L
★
2 0
-
8
0
R
1
Outlet Pressure Adjustment Ranges
†
Substitute
1 to 25 psig (0.07 to 1.7 bar)
T
2 to 50 psig (0.14 to 3.4 bar)
E
5 to 100 psig (0.34 to 6.9 bar)
K
Pipe Plug, Hex Socket
Hex Nipple
Union Adapter with Cap
Wall Mounting Bracket
1/4" PTF
1/4" PTF male
1/4" PTF to 1/4" tube (45° flare)
Strap Type: 5095-51
2891-97
18-006-067
18-006-068
Adapter only: 18-006-027
Cap only: 3302-50
Nitrogen Service
Carbon Dioxide Service
Cylinder Connector
Cylinder Connector
2" (50 mm) diameter, 1/4 PTF connection
0.906-14 RH external thread
0.830-14 RH internal thread
15 psig (1 bar): 18-013-082
CGA No. 580: 18-008-004
1.44" (27 mm) long nipple
30 psig (2 bar), UL Listed: 18-013-030
CGA No. 320: 18-008-002
60 psig (4 bar), UL Listed: 18-013-083
2.25" (57 mm) long nipple
100 psig (7 bar), UL Listed: 18-013-084
18-008-015
160 psig (11 bar), UL Listed: 18-013-085
Replacement gasket: 1390-02
300 psig (20 bar), UL Listed: 18-013-086
2000 psig(135 bar), UL Listed: 18-013-244
3000 psig (205 bar), UL Listed: 18-013-087
Inlet Fittings
Manifolds with integral check valves ††
Streamline Wye **
Check Valve, 1/4" PTF male to 1/4" tube (45° flare): 16-009-001
2 or 3 outlets, 1/4" PTF male to 1/4" tube (45° flare): 3228-54
1/4" NPT male to
Check Valve, 1/4" PTF male to 1/2-16 BSF: 16-009-002
2 or 3 outlets, 1/4" PTF male to 1/2-16 BSF: 3228-55
1/4" NPT female: 16-006-107
Check Valve, 1/4" PTF male to 1/4" PTF female: 16-009-003
4 or 5 outlets, 1/4" PTF male to 1/4" tube (45° flare): 3228-60
Check and Relief Valve,
4 or 5 outlets, 1/4" PTF male to 1/2-16 BSF: 3228-61
1/4" PTF male to 1/4" tube (45° flare): 16-006-107 Manifold extension, 1/4" PTF male to 1/4" PTF female: 2340-50
Single Outlet Fittings
Check Valve††
Check Valve††
Check and Relief Valve, *
Relief cracking pressure:
130 ± 4 psig
(9.0 ± 0.28 bar)
2 or 3 Port
4 or 5 Port
Manifold
Extension
Accessories
Multiple Outlet Fittings