R84, c84 beverage regulators – Norgren U.L. Listed Beverage Regulators User Manual
Page 3
R84, C84 Beverage Regulators
Littleton, CO USA
Phone 303-794-2611
Fax 303-795-9487
ALE-12-3
†† The listed check valves and manifolds with integral check valves are designed for use with Norgren R84 regulators and C84 regulator configurations. They are not
recommended for use with other regulators and regulator configurations unless separate pressure relief protection is provided in each of the outlet lines.
Ordering Information.
Models listed include integral relief valve with cracking pressure of 150 ± 5 psig (10.4 ± 0.33 bar), PTF threads,
relieving diaphragm, 5 to 125 psig (0.34 to 8.6 bar) outlet pressure adjustment range†. A gauge is not included.
Port
Model
Weight lb (kg)
1/4"
R84-200-MNLA
1.3 (0.59)
Pipe Plug, Hex Socket
Hex Nipple
Union Adapter with Cap
Wall Mounting Bracket
1/4" PTF
1/4" PTF male
1/4" PTF to 1/4" tube (45° flare)
Strap Type: 5095-51
2891-97
18-006-067
18-006-068
Adapter only: 18-006-027
Cap only: 3302-50
Nitrogen Service
Carbon Dioxide Service
Cylinder Connector
Cylinder Connector
2" (Ø 50 mm) diameter, 1/4" PTF connection
0.906-14 RH external thread
0.830-14 RH internal thread
15 psig (1 bar): 18-013-082
CGA No. 580: 18-008-004
1.44" (37 mm) long nipple
30 psig (2 bar), UL Listed: 18-013-030
CGA No. 320: 18-008-002
60 psig (4 bar), UL Listed: 18-013-083
2.25" (57 mm) long nipple
100 psig (7 bar), UL Listed: 18-013-084
18-008-015
160 psig (11 bar), UL Listed: 18-013-085
Replacement gasket: 1390-02
300 psig (20 bar), UL Listed: 18-013-086
2000 psig (135 bar), UL Listed: 18-013-244
3000 psig (205 bar), UL Listed: 18-013-087
Inlet Fittings
Check Valve, 1/4" PTF male to 1/4" tube (45°flare): 16-009-001
2 or 3 outlets, 1/4" PTF male to 1/4" tube (45°flare): 3228-54
Check Valve, 1/4" PTF male to 1/2-16 BSF: 16-009-002
2 or 3 outlets, 1/4" PTF male to 1/2-16 BSF: 3228-55
Check Valve, 1/4" PTF male to 1/4" PTF female: 16-009-003
4 or 5 outlets, 1/4" PTF male to 1/4" tube (45°flare): 3228-60
4 or 5 outlets, 1/4" PTF male to 1/2-16 BSF: 3228-61
Manifold extension, 1/4" PTF male to 1/4" PTF female: 2340-50
Single Outlet Fittings - Check Valves ††
2 or 3 Port
4 or 5 Port
Manifold
Extension
Accessories
Multiple Outlet Fittings - Manifolds with integral check valves ††
†
Outlet pressure can be adjusted to pressures in excess of, and less than, that specified. Do not use these units to control pressures outside of the specified range.