beautypg.com

R84 regulator and c84 regulator configurations, R84 regulator and c84 configurations – Norgren U.L. Listed Beverage Regulators User Manual

Page 2

background image

See Section ALE-25 for Accessories

Littleton, CO USA

Phone 303-794-2611

Fax 303-795-9487

R84 Regulator and C84 Configurations

Underwriters Laboratories, Inc. listed (file number
SA1089)

Integral relief valve easily replaced without
disassembly of regulator and without affecting relief
pressure setting

Back flow check valve, or manifold with integral
check valve at each outlet, can be installed in
regulator outlet port. Manifolds available with 3 or 5
outlets and include one outlet cap.

Relieving diaphragm allows outlet pressure setting to
be reduced even though the system is dead-ended.
Pressure downstream of check valves will not be
reduced.

Easily replaceable valve cartridge contains valve,
valve seat, valve spring, and filter element

Two high pressure ports (inlet and primary gauge)
and two regulated pressure ports (outlet and
secondary gauge)

Bonnet wrench hex same size as tank adapter - one
wrench fits both

UL Listed, Cylinder Gas Pressure Regulator

1/4" PTF Port Size, CO

2

Regulator for Soft Drink Carbonator

Technical Data

Fluid: Carbon dioxide. The R84 regulator is designed to be used exclusively as a

carbonator regulator in soft drink dispensing systems to control cylinder gas

(carbon dioxide) pressure to the carbonator tank. Other Norgren regulators

(R81 for soft drink syrup containers, R82 for beer, R83 for industrial cylinder

gases) are available for use in other systems.

Maximum pressure: 3000 psig (207 bar)

Operating temperature: 0° to 140°F (-18° to 60°C)

Integral relief valve cracking pressure:

150 ± 5 psig (10.4 ± 0.33 bar)

Materials:

Body: Brass

Bonnet: Zinc

Valve cartridge: Teflon, brass, stainless steel

Diaphragm: Acetal and nitrile

Relief valve: Brass, polycarbonate, nitrile, aluminum

Seals: Nitrile

NOTE

The integral relief valve on the R84 regulator does not meet the

requirements of Paragraph 4.5c of NSDA Pamphlet TD02, Installation

and Operational Procedures for Pressurized Soft Drink Dispensing

Systems, dated July,1980. The end cap on the relief valve is color coded

red for visual identification and is for use only on the Norgren R84

regulator.

ALE-12-2