R84 regulator and c84 regulator configurations, R84 regulator and c84 configurations – Norgren U.L. Listed Beverage Regulators User Manual
Page 2
![background image](/manuals/467631/2/background.png)
See Section ALE-25 for Accessories
Littleton, CO USA
Phone 303-794-2611
Fax 303-795-9487
R84 Regulator and C84 Configurations
●
Underwriters Laboratories, Inc. listed (file number
SA1089)
●
Integral relief valve easily replaced without
disassembly of regulator and without affecting relief
pressure setting
●
Back flow check valve, or manifold with integral
check valve at each outlet, can be installed in
regulator outlet port. Manifolds available with 3 or 5
outlets and include one outlet cap.
●
Relieving diaphragm allows outlet pressure setting to
be reduced even though the system is dead-ended.
Pressure downstream of check valves will not be
reduced.
●
Easily replaceable valve cartridge contains valve,
valve seat, valve spring, and filter element
●
Two high pressure ports (inlet and primary gauge)
and two regulated pressure ports (outlet and
secondary gauge)
●
Bonnet wrench hex same size as tank adapter - one
wrench fits both
UL Listed, Cylinder Gas Pressure Regulator
1/4" PTF Port Size, CO
2
Regulator for Soft Drink Carbonator
Technical Data
Fluid: Carbon dioxide. The R84 regulator is designed to be used exclusively as a
carbonator regulator in soft drink dispensing systems to control cylinder gas
(carbon dioxide) pressure to the carbonator tank. Other Norgren regulators
(R81 for soft drink syrup containers, R82 for beer, R83 for industrial cylinder
gases) are available for use in other systems.
Maximum pressure: 3000 psig (207 bar)
Operating temperature: 0° to 140°F (-18° to 60°C)
Integral relief valve cracking pressure:
150 ± 5 psig (10.4 ± 0.33 bar)
Materials:
Body: Brass
Bonnet: Zinc
Valve cartridge: Teflon, brass, stainless steel
Diaphragm: Acetal and nitrile
Relief valve: Brass, polycarbonate, nitrile, aluminum
Seals: Nitrile
NOTE
The integral relief valve on the R84 regulator does not meet the
requirements of Paragraph 4.5c of NSDA Pamphlet TD02, Installation
and Operational Procedures for Pressurized Soft Drink Dispensing
Systems, dated July,1980. The end cap on the relief valve is color coded
red for visual identification and is for use only on the Norgren R84
regulator.
ALE-12-2