6.6.77 Calibration Scale (Scale)

Page18, Address 63

Default = 0x4C CCCC (0.6)

The Scale register is used in the gain calibration to set the level of calibrated results of I-channel RMS. During
gain calibration, the Ix

RMS

results register is divided into the Scale register. The quotient is put into the Ix

GAIN

register. This is a two's complement value in the range of -1.0

value1.0, with the binary point to the right of

the MSB. Negative values are not used.

6.6.78 V-channel Zero-crossing Threshold (VZX

LEVEL

)

Page 18, Address 58

Default = 0x10 0000 (0.125)

VZX

LEVEL

is the level that the peak instantaneous voltage must exceed for the zero-crossing detection to

function. This is a two's complement value in the range of -1.0

value<1.0, with the binary point to the right of

the MSB. Negative values are not used.

6.6.79 I-channel Zero-crossing Threshold (IZX

LEVEL

)

Page 18, Address 24

Default = 0x10 0000 (0.125)

IZX

LEVEL

is the level that the peak instantaneous current must exceed for the zero-crossing detection to func-

tion. This is a two's complement value in the range of -1.0

value<1.0, with the binary point to the right of the

MSB. Negative values are not used.

MSB

LSB

-(2

0

)

2

-1

2

-2

2

-3

2

-4

2

-5

2

-6

2

-7

.....

2

-17

2

-18

2

-19

2

-20

2

-21

2

-22

2

-23

MSB

LSB

-(2

0

)

2

-1

2

-2

2

-3

2

-4

2

-5

2

-6

2

-7

.....

2

-17

2

-18

2

-19

2

-20

2

-21

2

-22

2

-23

MSB

LSB

-(2

0

)

2

-1

2

-2

2

-3

2

-4

2

-5

2

-6

2

-7

.....

2

-17

2

-18

2

-19

2

-20

2

-21

2

-22

2

-23