6.6.34 Current 2 Overcurrent Duration (I2Over

DUR

) – Page 17, Address 12

Default = 0x00 0000

Current 2 Overcurrent Duration, I2Over

DUR

, determines the count of OWR samples utilized to determine an

overcurrent event.

These are integers in the range of 0 to 8,388,607 samples. A value of zero disables the feature.

6.6.35 Current 2 Overcurrent Level (I2Over

LEVEL

) – Page 17, Address 13

Default = 0x7F FFFF

Current 2 Overcurrent Level, I2Over

LEVEL

, establishes a threshold at which an overcurrent event is triggered.

This is a two's complement value in the range of -1.0

value1.0, with the binary point to the right of the MSB.

Negative values are not used.

6.6.36 Voltage 1 Swell Duration (V1Swell

DUR

) – Page 18, Address 46

Default = 0x00 0000

Voltage 1 Swell Duration, V1Swell

DUR

, determines the count of OWR samples utilized to determine a swell

event.

These are integers in the range of 0 to 8,388,607 samples. A value of zero disables the feature.

6.6.37 Voltage 1 Swell Level (V1Swell

LEVEL

) – Page 18, Address 47

Default = 0x7F FFFF

Voltage 1 Swell Level, V1Swell

LEVEL

, establishes a threshold at which a swell event is triggered.

This is a two's complement value in the range of -1.0

value1.0, with the binary point to the right of the MSB.

Negative values are not used.

6.6.38 Voltage 2 Swell Duration (V2Swell

DUR

) – Page 18, Address 50

Default = 0x00 0000
Voltage 2 Swell Duration, V2Swell

DUR

, determines the count of OWR samples utilized to determine a swell

event.
These are integers in the range of 0 to 8,388,607 samples. A value of zero disables the feature.

MSB

LSB

0

2

22

2

21

2

20

2

19

2

18

2

17

2

16

.....

2

6

2

5

2

4

2

3

2

2

2

1

2

0

MSB

LSB

-(2

0

)

2

-1

2

-2

2

-3

2

-4

2

-5

2

-6

2

-7

.....

2

-17

2

-18

2

-19

2

-20

2

-21

2

-22

2

-23

MSB

LSB

0

2

22

2

21

2

20

2

19

2

18

2

17

2

16

.....

2

6

2

5

2

4

2

3

2

2

2

1

2

0

MSB

LSB

-(2

0

)

2

-1

2

-2

2

-3

2

-4

2

-5

2

-6

2

-7

.....

2

-17

2

-18

2

-19

2

-20

2

-21

2

-22

2

-23

MSB

LSB

0

2

22

2

21

2

20

2

19

2

18

2

17

2

16

.....

2

6

2

5

2

4

2

3

2

2

2

1

2

0