6. Commissioning, operation
2162679.01
2157306.0X
2123568.0X
Cable gland M20 x 1.5
with 1 m cable
Safety instructions for installation
■
Follow the installation and safety instructions within the
operating instructions.
■
Install instruments in accordance with the manufacturer's
instructions and the valid standards and regulations.
■
The instruments do not provide for incorporated overcurrent protectors!
■
In order to prevent the contacts from welding through overload, suitable
protection systems must be implemented by the operator!
Precise wiring schemes can be seen in the following connection diagram. In
addition both the pin assignment and the required power supply are stated on
the product label of the case circumference.
Electrical connection via:
■
Terminal box or angular connector per DIN 43651
M20 x 1.5
850.33 2nd contact
850.3 1st contact
Cable terminal box
or electrical connection via:
■
Cable gland and cable
2162679.0X
850.33
2nd
contact
850.3
1st
contact