Kramer Protocol 3000

29

29

11.2 Kramer Protocol 3000 Syntax

Protocol 3000 communicates at a data rate of 115200 baud, no parity, 8 data
bits and 1 stop bit.

11.2.1 Host Message Format

Start

Address (optional)

Body

Delimiter

#

Destination_id@

Message

CR

11.2.2 Simple Command

Command string with only one command without addressing:

Start

Body

Delimiter

#

Command SP Parameter_1,Parameter_2,…

CR

11.2.3 Command String

Formal syntax with commands concatenation and addressing:

Start

Address

Body

Delimiter

#

Destination_id@

Command_1 Parameter1_1,Parameter1_2,…|

Command_2 Parameter2_1,Parameter2_2,…|
Command_3 Parameter3_1,Parameter3_2,…|…

CR

11.2.4 Device Message Format

Start

Address (optional)

Body

delimiter

~

Sender_id@

Message

CR LF

11.2.5 Device Long Response

Echoing command:

Start

Address (optional)

Body

Delimiter

~

Sender_id@

Command SP [Param1 ,Param2 …] result

CR LF

CR = Carriage return (ASCII 13 = 0x0D)
LF = Line feed (ASCII 10 = 0x0A)
SP = Space (ASCII 32 = 0x20)