2 kramer protocol 3000 syntax, 1 host message format, 2 simple command – Kramer Electronics VS-88HD User Manual
Page 33: 3 command string, 4 device message format, 5 device long response, Kramer protocol 3000 syntax, Host message format, Simple command, Command string
Kramer Protocol 3000
29
29
11.2 Kramer Protocol 3000 Syntax
Protocol 3000 communicates at a data rate of 115200 baud, no parity, 8 data
bits and 1 stop bit.
11.2.1 Host Message Format
Start
Address (optional)
Body
Delimiter
#
Destination_id@
Message
CR
11.2.2 Simple Command
Command string with only one command without addressing:
Start
Body
Delimiter
#
Command SP Parameter_1,Parameter_2,…
CR
11.2.3 Command String
Formal syntax with commands concatenation and addressing:
Start
Address
Body
Delimiter
#
Destination_id@
Command_1 Parameter1_1,Parameter1_2,…|
Command_2 Parameter2_1,Parameter2_2,…|
Command_3 Parameter3_1,Parameter3_2,…|…
CR
11.2.4 Device Message Format
Start
Address (optional)
Body
delimiter
~
Sender_id@
Message
CR LF
11.2.5 Device Long Response
Echoing command:
Start
Address (optional)
Body
Delimiter
~
Sender_id@
Command SP [Param1 ,Param2 …] result
CR LF
CR = Carriage return (ASCII 13 = 0x0D)
LF = Line feed (ASCII 10 = 0x0A)
SP = Space (ASCII 32 = 0x20)