Your VS-88HD 8x8 HD-SDI Matrix Switcher
6
Table 1: Front Panel VS-88HD 8x8 HD-SDI Matrix Switcher
#
Feature
Function
1
IR Receiver
The yellow LED illuminates when receiving signals from the infrared remote
control transmitter
2
POWER LED
Illuminates when the unit is ON
3
ALL Button
Pressing ALL followed by an INPUT button, connects that input to all outputs
4
OFF Button
Pressing OFF+OUT disconnects that output from the inputs;
pressing OFF+ALL disconnects all the outputs;
a long press toggles between dual link and normal mode (see section
5
IN SELECT Buttons
Select the input to switch to the output;
long presses on buttons IN1 to IN5 change the genlock timing (see
6
OUT SELECT Buttons Select the output to which the input is switched
7
STO (STORE) Button
Pressing STO followed by an IN / OUT button stores the current setting
8
RCL (RECALL) Button Pressing the RCL button and the corresponding INPUT / OUTPUT key recalls a
setup from the non-volatile memory
9
LOCK Button
A long press toggles activation/inactivation of the front panel buttons;
pressing LOCK+OUT2 selects Protocol 2000; pressing LOCK+OUT3 selects
Protocol 3000
10
TAKE Button
Pressing TAKE toggles the mode between the CONFIRM mode and the AT
ONCE mode (user confirmation per action is unnecessary)
11
7-segment Display
Displays the selected input switched to the output (marked above each input)
Table 2: Rear Panel VS-88HD 8x8 HD-SDI Matrix Switcher
#
Feature
Function
12
GENLOCK BNC Connector
Connects to the genlock source
13
TERM HI-
Z/75Ω Pushbutton Press to terminate the genlock source (75Ω) or release for looping
14
LOOP BNC Connector
Connects to the genlock connector of the next unit in the line
15
INPUT BNC Connectors
Connects to the serial digital video sources
16
RS-232 9-pin D-sub (F) Port
Connects to the PC or the remote controller
17
PROG/RS-485 TERM
DIP-switches
PROG DIP-switch enables microcontroller firmware upgrade
RS-485 TERM DIP-switch terminates the RS-
485 line with a 120Ω load
18
RS-485 Terminal Block Port
Pins B (-) and A (+) are for RS-485;
Pin G may be connected to the shield (if required)
19
ETHERNET RJ-45 Connector Connects to the PC or other Serial Controller through computer networking
LAN
20
MACH # DIP-switches
DIP-switches 1-4 for setting the Machine Address of the unit
21
ETH RESET Button
Press to reset to factory default definitions
22
:
IP number
− 192.168.1.39, Mask – 255.255.0.0, Gateway – 0.0.0.0
OUTPUT BNC Connectors
Connect to the serial digital video acceptors
23
REMOTE IR 3.5mm Mini Jack Connect to an external IR receiver unit for controlling the machine via an IR
remote controller (instead of using the front panel IR receiver)
24
Power Connector with Fuse
AC connector enabling power supply to the unit
25
Power Switch
Turns the power to the unit ON and OFF
1 First disconnect the power cord and then connect it again while pressing the ETH Factory Reset button. The unit powers up
and loads its memory with the factory default definitions and erases all stored presets
2 Optional. Can be used instead of the front panel (built-in) IR receiver to remotely control the VS-88HD (only if the internal
IR connection cable has been installed) (See section