beautypg.com

1 set ip port sub-menu, 2 set serial port sub-menu, On 7.1.1 – Kramer Electronics VS-808TP User Manual

Page 20: On 7.1.2

background image

16

VS-808TP - Operating the VS-808TP Locally via the Front Panel Buttons

7.1.1

Set IP Port Sub-menu

The parameters in the Set IP Port sub-menu set the network IP values and reset

the device. For factory defaults see

Section 10

.

Parameter

Description

Options

IP Address

Sets the IP network address

Any valid IP address

Subnet Mask

Sets the IP network mask

Any valid subnet mask

Gateway

Sets the IP gateway address

Any valid gateway address

Default IP Settings

Sets the IP settings to the factory default (see

Section 10.1

)

Save and Reset the Device

Saves changes made to settings and resets the device

Exit Without Save

Exits without saving any changed settings

7.1.2

Set Serial Port Sub-menu

The parameters in the Serial Port sub-menu set the serial port parameter values.

For factory defaults see

Section 10

.

Parameter

Description

Options

Serial Port
Address

Sets the serial
machine number

1 to 16

Baud Rate

Sets the serial port
baud rate in bps

9600, 19200, 38400 or 115200

Serial Port Mode

Sets the serial port
mode of
communication

RS-232
1. RS-232 (Data): Exchange data with the remote
output acceptors
2. RS-232 (Control): Accept Kramer Protocol 2000
commands to switch the VS-808TP
3. RS-422/485: No function
RS-422/RS-485
1. RS-232 (Data): Exchange data with the remote
output acceptors
2. RS-232 (Control): No function
3. RS-422/485: Accept Kramer Protocol 2000
commands to switch the VS-808TP
BYPASS
1. RS-232 (Data): Exchange data with the remote
output acceptors
2. RS-232 (Control): Accept Kramer Protocol 2000
commands to switch the VS-808TP
3. RS-422/485: No function

Default Serial
Settings

Sets the serial port parameters to the factory default (see

Section 10.1

)

Save and Reset
the Device

Save any changes to settings and reset the device

Exit Without
Save

Exit without saving and changed settings