Figure 4: crossed cable rs-232 connection – Kramer Electronics VS-808TP User Manual
Page 13
![background image](/manuals/465114/13/background.png)
VS-808TP - Connecting the VS-808TP
9
6.2.1
Connecting an RS-232 Serial Controller to the VS-808TP RS-232
Control Port
You can connect to the unit (the RS-232 CONTROL port) via a crossed RS-232
connection, using for example, a PC. A crossed cable or null-modem is required
as shown in method A and B respectively. If a shielded cable is used, connect the
shield to pin 5.
Method A (
)—Connect the RS-232 9-pin D-sub port on the unit via a
crossed cable (only pin
2
to pin
3
, pin
3
to pin
2
, and pin
5
to pin
5
need be
connected) to the RS-232 9-pin D-sub port on the PC.
Note: There is no need to connect any other pins.
Figure 4: Crossed Cable RS-232 Connection
Hardware flow control is not required for this unit. In the rare case where a
controller requires hardware flow control, short pin 1 to 7 and 8, and pin 4 to 6 on
the controller side.
Method B (
)—Connect the RS-232 9-pin D-sub port on the unit via a
straight (flat) cable to the null-modem adapter, and connect the null-modem
adapter to the RS-232 9-pin D-sub port on the PC. The straight cable usually
contains all nine wires for a full connection of the D-sub connector. Because the
null-modem adapter (which already includes the flow control jumpering described
in Method A above) only requires pins 2, 3 and 5 to be connected, you are free to
decide whether to connect only these 3 pins or all 9 pins.
Figure 5: Straight Cable RS-232 Connection with a Null Modem Adapter
1
2
6
3
7
4
8
5
9
1
2
6
3
7
4
8
5
9
PC
1
2
6
3
7
4
8
5
9
to PC
Null-Modem
Adapter