Figure 4d – Graymills Liftkleen L-Series OMI User Manual
Page 23

22
FIGURE 4d
ANTI-TIE DOWN SYSTEMS
APPLICATION: All units with Anti-Tie Down
devices
DESCRIPTION: Pneumatic system consisting of:
1. Control box with a 2 position (ON-OFF)
Oscillate Selector Switch, Start, Reset, and
Emergency Stop Buttons.
2. Anti-Tie Down Device
3. Mechanical type valves
4. Lid Lockout
SEQUENCE OF OPERATIONS:
START: Lid Closed, Rack Down
LOADING:
1. Depress both buttons on the Anti-Tie Down
device simultaneously and hold until the lid
opens completely and the rack is in the fully
upright position, then release the Anti-Tie
Down buttons
AGITATION:
1. Turn Oscillate Selector switch to ON position
2. Depress both buttons on the Anti-Tie Down
device simultaneously and hold until the rack
is in the down position and the lid closes
completely, then release the Anti-Tie Down
buttons
SOAK:
1. Turn Oscillate Selector to OFF position
2. Depress both buttons on the Anti-Tie Down
device simultaneously and hold until the rack
is in the down position and the lid closes
completely, then release the Anti-Tie Down
buttons
LID LOCKOUT: Lid activated switch overrides all
other selector switches and prevents rack from
going to the UP position before the lid is fully
opened.
See Drawing #796PD37642-1