13
TABLE 2
LIFTKLEEN PLATFORM LOAD CAPACITY
LIFTKLEEN
CYL.
WORKING LOAD AT VARIOUS AIR PRESSURES
BASIC MODEL
DIA.
70 PSI
80 PSI
90 PSI
100 PSI
110 PSI
LKR 36
4˝
330
400
480
550
630
LKR 36 IL
5˝
425
740
860
980
*___
LKR 48
4˝
230
300
380
450
530
LKR 48 IL
5˝
525
640
760
880
990
LKR 60
5˝
325
440
560
680
790
LKR 60 IL
5˝ (2)
1150
1385
1620
1850
*2090
LKD 60
5˝
325
440
560
680
790
LKD 60 IL
5˝ (2)
1150
1385
1620
1850
*2090
LKD 72 IL
5˝ (2)
1050
1285
1520
1750
1990
IL = Increased Lift Capacity because of larger cylinder.
*___ Exceeds rated capacity.
NOTE: The above working loads are calculated at 60% of gross cylinder capacity less rack weight. This is required
for good agitation.
Average agitation cycle (up and down) will be approximately 30 per minute. This will vary with the load, air
pressure and volume.
Pump agitation is continuous regardless of load.
TABLE 3
LIFTKLEEN AIR CONSUMPTION
(5 IN. STROKE)
STROKES
“UP” ONLY
“UP” AND “DOWN”
CYLINDER
PER
(SCFM)
(SCFM)
SIZE (IN.)
MODELS
MINUTE
60 PSI
80 PSI
100 PSI
60 PSI
80 PSI
100 PSI
4
LKR-36, -48
20
5.4
6.9
8.4
8.7
10.8
13.0
5
LKR-36, -48(Heavy)
20
8.5
10.8
13.2
13.6
17.1
20.5
LKR-60
LKD-60, -72
5 (2)
LKR-60
20
17.2
21.9
26.5
27.5
34.5
41.3
LKD-60, -72
(Heavy Lift)
4
LKR-36, -48
40
7.2
9.2
11.2
11.6
14.4
17.4
5
LKR-36, -48(Heavy)
40
11.4
14.4
17.6
18.2
22.8
27.4
LKR-60
LKD-60, -72
5 (2)
LKR-60
40
23.8
29.2
35.4
36.8
46.0
55.2
LKD-60, -72
(Heavy Lift)