TROUBLESHOOTING GUIDE
ELECTRICAL
CONDITION
POSSIBLE CAUSE
CORRECTION
Pump does not run.
Electrical service to motor is not
Check electrical supply and
correct.
correct.
Motor is burned out.
Replace motor or return pump to
factory for repair.
Pump runs but does not agitate.
Pump rotation is incorrect
Reverse any two electrical supply
(3 Phase Power).
lines to motor. (Correct rotation is
CCW - see label.)
Pump runs but is noisy. (Minor
Cavitation due to low liquid level.
Raise liquid to correct level.
sound created by liquid flow
through pump is normal.)
Tank does not reach operating
Electrical supply is not on.
Check and correct electric
temperature.
service.
Thermostat is set too low.
Raise thermostat temperature.
Faulty heater.
Check and replace if necessary.
Heating contactor is faulty.
Check and replace if necessary.
Tank takes too long to heat up.
Electrical supply voltage is
Check and correct if necessary.
(See Figure 12 for heat-up times).
incorrect.
One element of the tri-element
Check heater elements and
heater is burned out.
replace heater if necessary.
Excessive heat loss due to
Lower rack and lid when unit is
open lid.
not in use.
Heater Timer
Tank does not reach operating
115V, Single phase power
Turn on.
temperature.
supply off.
Timer actuating tripper not
Attach tripper.
attached.
Timer actuating tripper incorrectly
Position correctly.
positioned.
Faulty timer.
Replace.
Faulty transformer.
Replace.
Faulty contactor.
Replace.