14
TABLE 4
LIFTKLEEN ELECTRICAL CURRENT REQUIREMENTS
HEATER AMPERAGE
VOLTAGE/PHASE
1 Heater (4500 W)
2 Heaters (9000 W)
3 Heaters (13,500 W)
240 V/1-Ph
18.8
37.5
56.3
240 V/3-Ph
10.8
21.7
32.5
480 V/3-Ph
5.4
10.8
16.2
575 V/3-Ph
4.5
9.0
13.5
Note: Add the corresponding motor amps below to the above heater amps to find the full load amperage.
VOLTAGE/PHASE
MOTOR AMPERAGE (1-1/2 H.P., 1725 RPM)
230 V/1-Ph
10.5
230 V/3-Ph
4.6
460 V/3-Ph
2.3
575 V/3-Ph
2.0
TABLE 5
LIFTKLEEN FILTERS
Filter Housing #742-06154 is used with the following cartridge assemblies.
Cartridge
Particle Retention
Element
Cartridge #
Type
Size
Number
742-06317
Stacked Disc
3-5 Micron
742-06318
742-06319
Disposable Bag
50 Micron
742-06320
742-06332
Strainer
590 Micron (30 Mesh)
742-06331
742-06243
Strainer
150 Micron (100 Mesh)
742-06244
_
Strainer*
100 Micron (150 Mesh)
742-06379
_
Strainer*
74 Micron (200 Mesh)
742-06380
_
Strainer *
30 Micron (2140 Mesh)
742-06381
*These are optional elements (not cartridge assemblies). They can be used in place of the standard
elements (30 Mesh and 100 Mesh) in cartridge assemblies #742-06332 and 742-06243.