Cycle Timer

Platform oscillates but does not

Lid cylinder fails to operate.

Check and manually activate.

raise automatically after cycle.

Solenoid valve stuck. (Only on

Clean or replace.

LKT-3)

Solenoid inoperative.

Replace after checking electrical
characteristics.

Platform does not agitate.

Solenoid valve stuck. (Only on

Clean or replace.

LKT-3)

Solenoid inoperative. (Only on

Replace after checking electrical

LKT-3)

characteristics.

Faulty air valve.

Replace.

Faulty timer.

Replace.

PNEUMATIC

Lift platform is jammed.

Parts lodged in lifter mechanism.

Reverse unit and remove parts.

Platform does not operate

Air supply is not connected.

Check and connect air supply.

properly.

Master on/off valve is in “OFF”

Turn to “ON” position.

position.

Main air pressure regulator set

Adjust regulator to 80 psi

too low.

minimum.

Speed control mufflers adjusted

Correct adjustment.

incorrectly.

Pneumatic air control supply line

Check and repair as required.

pinched or disconnected.

CONDITION

POSSIBLE CAUSE

CORRECTION