Graymills Liftkleen L-Series OMI User Manual
Page 11

10
Cycle Timer
Platform oscillates but does not
Lid cylinder fails to operate.
Check and manually activate.
raise automatically after cycle.
Solenoid valve stuck. (Only on
Clean or replace.
LKT-3)
Solenoid inoperative.
Replace after checking electrical
characteristics.
Platform does not agitate.
Solenoid valve stuck. (Only on
Clean or replace.
LKT-3)
Solenoid inoperative. (Only on
Replace after checking electrical
LKT-3)
characteristics.
Faulty air valve.
Replace.
Faulty timer.
Replace.
PNEUMATIC
Lift platform is jammed.
Parts lodged in lifter mechanism.
Reverse unit and remove parts.
Platform does not operate
Air supply is not connected.
Check and connect air supply.
properly.
Master on/off valve is in “OFF”
Turn to “ON” position.
position.
Main air pressure regulator set
Adjust regulator to 80 psi
too low.
minimum.
Speed control mufflers adjusted
Correct adjustment.
incorrectly.
Pneumatic air control supply line
Check and repair as required.
pinched or disconnected.
CONDITION
POSSIBLE CAUSE
CORRECTION