Figure 4b – Graymills Liftkleen L-Series OMI User Manual
Page 21
![background image](/manuals/464753/21/background.png)
20
FIGURE 4b
PNEUMATIC SYSTEMS
APPLICATION: Hot units with pneumatic lid
DESCRIPTION: Pneumatic system consisting of:
1. Control box with a 2 position (ON-OFF)
Oscillate Selector Switch, Start, Reset, and
Emergency Stop Buttons.
2. Mechanical type valves
3. Lid Lockout.
SEQUENCE OF OPERATIONS:
START: Lid Closed, Rack Down
LOADING:
1. Depress Reset button, lid will close
automatically
AGITATION:
1. Turn Oscillate Selector switch to ON position
2. Depress Start Button, lid will close
automatically
SOAK:
1. Turn Oscillate Selector to OFF position
2. Depress Start button, lid will close
automatically
LID LOCKOUT: Lid activated switch overrides all
other selector switches and prevents rack from
going to the UP position before the lid is fully
opened.
See Drawing #796PD37641