Graymills Liftkleen L-Series OMI User Manual

Page 12

background image

11

No action when selector

Air supply off.

Check and turn on.

switch is moved.

Pneumatic air control lines

Check and repair as required.

pinched or disconnected.

Air pressure at incorrect setting.

Check and adjust to 80 psi on
supply.

Faulty selector switch.

Replace switch.

Speed control mufflers adjusted

Correct adjustment.

incorrectly.

Sticking power valve due to

Disconnect all lines to cylinder

condensation, etc.

and cycle unit. Reconnect
cylinder.

Platform raises to “Up”

Air supply line to control box

Check and correct.

position even though control

is cut, pinched, or shut off.

selector knob is set at another
position.

Platform will not move from

Air supply line to control box

Check and correct.

“Up” position.

is cut, pinched, or shut off.

Lid does not open.

Air supply to lid control too

Check for 80 psi minimum

low or off. Speed control

air pressure.

improperly adjusted.

Lid opens too fast or

Speed control improperly

Adjust – turn adjusting screws in

too slowly.

adjusted.

to slow opening, out to speed up.

Lid closes too fast or

Same as above.

Same as above.

too slowly.

CONDITION

POSSIBLE CAUSE

CORRECTION