FIGURE 4c

PNEUMATIC SYSTEMS

APPLICATION: Cold units with pneumatic lid

DESCRIPTION: Pneumatic system consisting of:

1. Control box with a 2 position (ON-OFF)

Oscillate Selector Switch, Start, Reset, and
Emergency Stop Buttons

2. Mechanical type valves
3. Lid Lockout
4. Fire Safety Circuit
5. Pneumatic Lid (required)

SEQUENCE OF OPERATIONS:

START: Lid Closed, Rack Down

LOADING:
1. Depress Reset button, lid will close

automatically

AGITATION:
1. Turn Oscillate Selector switch to ON position
2. Depress Start Button, lid will close

automatically

SOAK:
1. Turn Oscillate Selector to OFF position
2. Depress Start button, lid will close

automatically

LID LOCKOUT: Lid activated switch overrides all
other selector switches and prevents rack from
going to the UP position before the lid is fully
opened.

FIRE SAFETY CIRCUIT: Automatically lowers
rack to the bottom of the tank and closes lid in the
event of a fire inside the tank and overrides the
selector switches and intermediate stop. The
safety circuit is activated by a Graymills fusible
vent tube which, when it melts, vents a
momentary air signal.

See Drawing #796PD37672