19
FIGURE 4a
PNEUMATIC SYSTEMS
APPLICATION: Hot units with manual lid
DESCRIPTION: Pneumatic system consisting of:
1. Control box with a 2 position (ON-OFF)
Oscillate Selector Switch, Start, Reset, and
Emergency Stop Buttons.
2. Mechanical type valves
3. Lid Lockout.
SEQUENCE OF OPERATIONS:
START: Lid Closed, Rack Down
LOADING:
1. Manually open lid
2. Depress Reset button.
AGITATION:
1. Turn Oscillate Selector switch to ON position
2. Depress Start Button
3. Manually close lid
SOAK:
1. Turn Oscillate Selector to OFF position
2. Depress Start button.
3. Manually close lid
LID LOCKOUT: Lid activated switch overrides all
other selector switches and prevents rack from
going to the UP position before the lid is fully
opened.
See Drawing #796PD37643