MAINTENANCE
Inspecting The Hydraulic Fluid Level
Check the fluid level in the reservoir after every 10 hours of use. Drain and replenish the reservoir with Power Team
hydraulic fluid after every 300 hours of use approximately.
Air Hydraulic Pump
For pumps with a 105 cubic inch (1.71) reservoir capacity
Electric Hydraulic Pump
For pumps with a 2 gallon (7.61) reservoir capacity
The fluid level should be 1/2 inch (12.7 mm) from the filler /
vent cap with all cylinders retracted.
The fluid level should be 1-3/4 inch (44.5 mm) from the filler /
vent cap with all cylinders retracted.
For Machines With:
SPX Power Team
Orange & White Cylinder with Black Letters
White & Black Pump
Enerpac
Yellow Cylinder with Black Letters
Yellow & Black Pump
Use: AW 46 - Non Foaming Hydraulic Fluid
or
Flame Out # 220 Fire Resistant Hydraulic Fluid
Use: ISO 7 HF 101 Gal
or
ISO 32 HF 100 Qt.
or
Mobil DTE 24 Hydraulic Oil is Compatible with Enerpac Components
Refilling The Reservoir
If additional fluid must be added to reservoir,
use only manufacturer suggested hydraulic fluid.
Clean the entire area around the filler plug before adding fluid to the reservoir.
Remove the filler plug and insert a clean funnel with filter.
The cylinder must be fully retracted and the air supply disconnected when adding the fluid to the reservoir.